SPECIFICATIONS
Load Rating: 13 amps @ 230 volts
Power Requirement (no load): 6 watts
Surge Let-Through Voltage (6000-volt surge): 0 volts
IEC/EN; 61643-1 Performance Rating: Grade A, Class 1, Mode 1
EMI/RFI Filter, Normal Mode (50-ohm load): 40dB @ 100kHz, 50dB @ 300kHz; 50dB @ 3MHz; 50dB @ 30MHz
EMI/RFI Filter, Common Mode (50-ohm load): 18dB @ 300kHz; 30dB @ 1MHz; 50dB @ 5MHz; 50dB @ 20MHz
Maximum Applied Surge Voltage: 6000 volts*
Maximum Applied Surge Current: Unlimited, due to current limiting*
Maximum Applied Surge Energy: Unlimited, due to current limiting*
Endurance (C62.41-1991 Category B3 pulses): 1 kV>500,000; 3 kV>10,000; 6 kV>1000
Undervoltage Shutdown: 180 volts (auto resetting)
Overvoltage Shutdown: 280 volts (auto resetting)
Maximum Load Inrush Current During Power-up: 1000 Joules
Remote Turn-on Applied Voltage Range: 5 to 30 volts DC
Remote Turn-on Current Draw:
Contact Closure: 1.5mA
5V DC Applied Voltage: 0.1mA
12V DC Applied Voltage: 1.5mA
24V DC Applied Voltage: 5.0mA
Auxiliary Relay Contact Rating: 30 Volts at 1 Amp
LED Output: 12 volts DC, maximum 20 mA (resistor required)
Dimensions: 1.75"H x 19"W x 10.5"D (4.5 x 48.3 x 26.7cm)
Weight: 11 lbs (5.0 kg)
Temperature Range: 5° to 35° C
Humidity Range: 5% to 95% R.H., non-condensing
*1.2 x 50µs pulse, industry standard combination wave surge, as per IEEE C62.41 |
FEATURES
- Magnetic shielding steel enclosure
- 9' power cord
- 10 earthed AC receptacles on rear panel (8 switched, 2 always on)
- Front panel courtesy receptacle
- Advanced Series Mode® Surge Elimination
- Advanced impedance Tolerant® EMI/RFI filtering
- SurgeX ICE® inrush current elimination
- COUVS® catastrophic over/under voltage shutdown
- Thermal circuit breaker overload protection
- Self-test circuit with visual Indicator
- 10-year warranty
- Engineered in the U.S.A.
TECHNICAL DESCRIPTION
The SX1213RTi shall be a one-rack-space unit in a magnetic shielding steel enclosure. It shall operate from 230 volts AC and have a 9-foot power cord. There shall be 10 earthed AC receptacles on the back panel, with 8 switched and 2 always on. The unit shall have a front-panel courtesy receptacle and remote-control
capability with a visual indicator. Overall dimensions shall be 4.5cm x 48.3cm x 26.7cm (1.75"H x 19"W x 10.5"D). Weight shall be 5Kg (11 Lbs).
The SX1213RTi shall have a load rating of 13 amps at 230 volts, a self-test circuit with visual indicator, and provide EMI/RFI filtering, inrush current elimination and catastrophic over/under-voltage shutdown. It shall meet Grade A, Class 1, Mode 1 guidelines for powerline surge suppressors and withstand at least 1000 occurrences of surge pulse voltages up to 6000 volts.
 Countries Included in this Region |
UK Ireland Sri Lanka Bahrain UAE Qatar Yemen
|
Oman Cyprus Malta Gibraltar Botswana Ghana Hong Kong |
Macau Brunei Malaysia Singapore Indonesia Kenya Uganda |
Nigeria Mauritius Iraq Tanzania Saudi Arabia |
|